Send Message
Home ProductsHigh TDS Ro Membrane

6000 TDS High Tds Ro Membrane For Water Purifier System Working Up Lp-4040

China Hangzhou Haina Environmental Protection Tech Co., Ltd. certification
China Hangzhou Haina Environmental Protection Tech Co., Ltd. certification
I'm Online Chat Now

6000 TDS High Tds Ro Membrane For Water Purifier System Working Up Lp-4040

6000 TDS High Tds Ro Membrane For Water Purifier System Working Up Lp-4040
6000 TDS High Tds Ro Membrane For Water Purifier System Working Up Lp-4040 6000 TDS High Tds Ro Membrane For Water Purifier System Working Up Lp-4040 6000 TDS High Tds Ro Membrane For Water Purifier System Working Up Lp-4040 6000 TDS High Tds Ro Membrane For Water Purifier System Working Up Lp-4040

Large Image :  6000 TDS High Tds Ro Membrane For Water Purifier System Working Up Lp-4040

Product Details:
Place of Origin: Hangzhou,China
Brand Name: HYNAMO/OEM
Certification: CE, RoHS, ISO9001, NSF
Model Number: 4040-LP
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: 109.00cm*11.00cm*11.00cm
Delivery Time: depend on quantity
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 30000 PCS /Month
Detailed Product Description
Type: Reverse Osmosis Membrane Salt Rejection Rate: 99.4%
Capacity: 1900GPD Recovery Rate: 15%
Operation Pressure: 350psi Weight: 3.8KG
Warranty: 3 Years Packing: 1PCS/Carton
Highlight:

ro membrane high tds

,

6000 tds membrane

,

lp-4040

BW-4040 Working Up 6000TDS Reverse Osmosis RO Membrane for RO Water Purifier System

 

RO membranes, in general, remove 90% or more of the contaminants present in the water, including TDS. When the TDS levels of your water source changes, it will affect the quality of the purified water output from your reverse osmosis system.

 

High TDS from a reverse osmosis system can be caused by the membrane malfunctioning, poor water pressure, a restricted drain line, non-reverse osmosis water contamination, higher TDS going into the reverse osmosis system or re-mineralization of the reverse osmosis water. Therefore, we have developed membrane elements for high TDS environments, normally, can be working up to 5000ppm, some also can be working up to 6000ppm to 8000ppm according to customer's request for high TDS series.

 

6000 TDS High Tds Ro Membrane For Water Purifier System Working Up Lp-4040 0

 

SPECIFICATIONS

Model Number Description 4040-LP
rformance &
Test Condition
The Desalination Rate % 99.4%
Water Rate GDP 1900
The Test pressure 350psi
Test solution Temperature 25± 1ºC
Test Solution Concentration NaCl 6000ppm
Test solution pH value 6.5-7.5
Recovery Of Single-Branch Membrane Element 15%
Feed water SDI ≤5
  • When PH is above 10, the Maximum Temperature of Continuous Operation is 35ºC.
  • Under certain conditions, the presence of free chlorine and other oxidants in the water may cause serious membrane damage, which doesn't belong to product warranty range.

Operating Limit:

Maximum Operating Temperature 113ºF(45ºC)
Maximum Working Pressure 600psi(41.0 bar)
The high pressure drop 15psi (1.0bar)
Continuously operating PH range a 3-10
Short wash PH range (30min) b 2-12
Maximum feed water SDI SDI 5
Tolerance Of Free Chlorine <0.1ppm
Maximum pressure drop for single membrane element 15psi(0.1Mpa)

 

 

Dimension of Membrane Element

6000 TDS High Tds Ro Membrane For Water Purifier System Working Up Lp-4040 1

PROCEDURES

 

6000 TDS High Tds Ro Membrane For Water Purifier System Working Up Lp-4040 2

 

FAQ:
Q: How to buy your products?
A: we need some essential information include sewage sources, sewage quality ( COD, BOD,SS),Required Filtered water quality, designed technological process, site engineering conditions (contact us for details),then we will design the uitable solutions for you and prepare to give you best price.

Q: How to pay?
A: TT and L/C are acceptable and TT will be more appreciated. 30% deposit before producing, 70% balanced against the copy of B/L.

Q: What is the delivery time?
A: Usually within 15days. Also depends on order quantities.

Q: Can the package be customized by our own logo ?
A: Yes, the package can be customized your logo, but the MOQ will be higher for which we can discuss as per the specific orders.

Q: How to install after the products arriving destination?
A: We will provide detailed illustrations to you. And we can also provide guide to your workers how to use it and how to maintain
it.

Q:What's the certification do you have?
A: We have NSF, ISO9001, OHSAS18001, ISO14001 Certifications.
 