Send Message
Home ProductsReverse Osmosis Element

Low Fouling Ro Membranes Ultrafiltration Reverse Osmosis Brackish Water BW FR 10500GPD

China Hangzhou Haina Environmental Protection Tech Co., Ltd. certification
China Hangzhou Haina Environmental Protection Tech Co., Ltd. certification
I'm Online Chat Now

Low Fouling Ro Membranes Ultrafiltration Reverse Osmosis Brackish Water BW FR 10500GPD

Low Fouling Ro Membranes Ultrafiltration Reverse Osmosis Brackish Water BW FR 10500GPD
Low Fouling Ro Membranes Ultrafiltration Reverse Osmosis Brackish Water BW FR 10500GPD Low Fouling Ro Membranes Ultrafiltration Reverse Osmosis Brackish Water BW FR 10500GPD

Large Image :  Low Fouling Ro Membranes Ultrafiltration Reverse Osmosis Brackish Water BW FR 10500GPD

Product Details:
Place of Origin: Hangzhou, China
Brand Name: Hynamo/OEM/ODM
Model Number: 8040 FR
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: 106.00cm * 23.00cm * 23.00cm
Delivery Time: depend on quantity
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Detailed Product Description
Certification: ISO9001, RoHS, CE, NSF Type: Reverse Osmosis Membrane
Salt Rejection Rate: 99.5% Recovery: 15%
Operation Pressure: 225psi Nacl Solution: 2000TDS
Production: 10500GPD Warranty: 3 Years
High Light:

FR 8040

,

low fouling reverse osmosis membrane

,

low fouling ultrafiltration membrane

8-inch Brackish Water BW FR Membrane for RO Reverse Osmosis Water System

 

The difference between anti-fouling membrane and ordinary membrane :

 

1. The salt content of the influent water is different. The anti-fouling membrane allows the salt content of the influent water to be in the range of 0-10000ppm, while the ordinary membrane allows the salt content of the influent water to only be in the range of 0-2000ppm. Undoubtedly, the salt content of the influent water of the anti-fouling membrane has a wider application range and can meet the requirements of more types of water quality and water treatment systems.

 

Second, the operating pressure requirements are different. The operating pressure of the anti-fouling membrane is lower than that of ordinary membrane elements, so that the anti-fouling membrane can reduce the frequency of cleaning. After choosing our anti-fouling membranes, many customers will find that compared with ordinary membranes, the use of anti-fouling membranes reduces cleaning costs and operating costs.

 

Third, the pH value is different. Anti-fouling membranes have a wider pH range, which is key to effective cleaning. Since the pH value of the cleaning solution is the key to removing contaminants in the membrane element, the wider the pH value range that the membrane element can withstand, the better the cleaning effect. The higher the cleaning efficiency, the longer the cleaning interval, the shorter the time required for each cleaning and the lower the cleaning cost.

 

Fourth, the price is different. The price of anti-fouling membranes is higher than that of ordinary membranes, but anti-fouling reverse osmosis membranes are more resistant to pollution, have longer cleaning and replacement cycles, and have lower application costs than ordinary reverse osmosis membranes. In the industrial wastewater treatment industry, the anti-fouling membrane is much more cost-effective than ordinary membranes, and is the most suitable choice.

 

Performance

 

TYPE 8040-LP 8040-ULP 8040-XLP 8040-FR 8040-SW
Rejection Rate 99.5% 99.2% 98.5% 99.5% 99.7%
Permeate Flow GPD(m³) 10500(39.9) 10500(39.9) 10500(39.9) 10500(39.9) 6000(22.6)
Test Pressure psi(Mpa) 225(1.53) 150(1.02) 100(0.68) 225(1.53) 800(5.5)
Max. Feedwater TDS/ppm 5000 2000 1000 2000 32000
PH Rate Rang of Operation 2-11
Max. Operation Temperature 45ºC
Recovery Rate of Single Membrane 15% 15% 8%

 

Note:1. The Max. continous operation temperature is 35ºC when PH rate over 10.
2.In certain conditions,if would cause membrane breakage if the free chlorine or the other oxidant in feedwater.The production quality guarantee range is notincluded membrane breakage by oxiadation.

 

Membrane Dimentions


Anti-Pollution 8040 Fr Low Pressure Industrial Reverse Osmosis Membrane

 
Model No. A(mm) B(mm) C(mm)
8040-FR 1016 199 28.5

 

Low Fouling Ro Membranes Ultrafiltration Reverse Osmosis Brackish Water BW FR 10500GPD 1

 

FAQ:

1. Q: Do you provide samples ? is it free or extra ?
A: Yes, we could offer the sample for free charge but do not pay the cost of freight.
2. Q: Should we use our logo/brand?
A: Yes, OEM is absolutely supported. But for some items quatity is 500pcs.

3. Q: What is the filtering accuracy of RO membrane?
A: RO meembran filtering accuracy is 0.0001um.

4.RO membrene desalination rate and service life ?
A: RO meembran desalination rate more 98%,service life according to water quality 2-3years
5. Q: What is the payment?
A: Usually we offer two payment terms: by Alibaba or by TT. L/C and D/A.
6. Q: How long time have your company in water treatment?
A: We have more than 18 years experience in water treatment equipment/water treatment solution.

Contact Details
Hangzhou Haina Environmental Protection Tech Co., Ltd.

Contact Person: Mr. Robert Wang

Tel: 0086 134 2961 7413

Send your inquiry directly to us (0 / 3000)