NSF Certified 1000 Tds RO Membrane Large Flow 1000 Gpd Water Purifier for Commercial NSF Certified 1000 Tds RO Membrane Large Flow 1000 Gpd Water Purifier for Commercial NSF Certified 1000 Tds RO Membrane Large Flow 1000 Gpd Water Purifier for Commercial NSF Certified 1000 Tds RO Membrane Large Flow 1000 Gpd Water Purifier for Commercial

Large Image :  NSF Certified 1000 Tds RO Membrane Large Flow 1000 Gpd Water Purifier for Commercial

Product Details:
Place of Origin: Hangzhou,Zhejiang,China
Brand Name: OEM/ODM
Model Number: GT-3213-1000
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: 35.00cm * 35.00cm * 37.00cm
Delivery Time: depend on quantity
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Detailed Product Description
Certification: ISO9001, RoHS, CE, NSF Type: Reverse Osmosis Membrane
Salt Rejection Rate: 95% Recovery: 50%
Operation Pressure: 150psi Nacl Solution: 500ppm
Production: 1000GPD Warranty: 2 Years
High Light:

NSF Certified Membranes Ro 1000 Gpd

,

Membranes Ro 1000 Gpd Water Purifiers

,

1000 Gpd NSF Certified Membranes Ro

NSF Certified 1000 Tds RO Membrane Large Flow 1000 Gpd Water Purifier for Commercial

 

Reverse osmosis membrane separation technology as a new type of efficient separation, concentration, purification and purification technology, the past 30 years to develop rapidly, has been widely used in pure water preparation, seawater desalination and wastewater treatment and other industries. Reverse osmosis membranes are key components in reverse osmosis systems. At present, there are about hundreds of thousands of membrane module users in China, and they are increasing at a rate of 20% to 30% per year. In practical applications, the membrane elements will occur to varying degrees of pollution, resulting in an increase in the pressure difference between the inlet and outlet of the system, a decrease in water production, and a decrease in the desalination rate, which in turn affects the normal operation of the reverse osmosis system, therefore, it is necessary to set up a reverse osmosis cleaning system to effectively clean it, maximize the recovery of the performance of the contaminated membrane element, so that the membrane can run more effectively and sustainably. How to analyze and effectively clean the pollution generated in the operation of the reverse osmosis membrane has received more and more attention.

 

Performance

TYPE GT-3213-1000
Rejection Rate 95%
Permeate Flow GPD(m³) 1000(3.8)
Test Pressure 100psi(0.7MPa)
Max. Feedwater TDS 1000
PH Rate Rang of Operation 3-10
Max. Operation Temperature 45ºC
Recovery Rate of Single Membrane 50%

 

Operating Limits

Max.Operating Pressure 125 psi (860 KPa) Max. Feed Flow Rate 2.0gpm(7.6lpm)
Max.Operating Temperature 45ºC (113ºF) pH Range, Continuous Operation 2-11
Max. Feed SDI15 5 pH Range,Short-term Rinse 1-13
* pH>10,Max.temperature of continuous operations is 35ºC (90ºF) Max.Chlorine Concentration <0.1 ppm

 

Note:1. The Max. continous operation temperature is 35ºC when PH rate over 10.
2.In certain conditions,if would cause membrane breakage if the free chlorine or the other oxidant in feedwater.The production quality guarantee range is notincluded membrane breakage by oxiadation.

Installation Instructions

Unscrew the nut on the membrane shell cover at the inlet water connection end, take out the inlet water pipe, then use the membrane shell wrench to loose the membrane shell cover. Take the RO membrane from its packaging, put the end of the membrane with 2 O-rings into the RO membrane shell and push it in, finally screw the membrane shell cover back on, and tighten it with membrane shell wrench, put the inlet water pipe back into the inlet water connector and screw the nut tightly, then push the membrane shell card into the large single clip.

Why choose us :

1. Professional manufacturer : More than 18 years experience in prodcuing pure water treatment system .

2. Strict time control : Ensure delivery time.

3. Factory strength: Automatic production line, more than 100 workers.

4. After-sales service : 24 Hours online service.

5. Customized is available. Sample order is available.

 

NSF Certified 1000 Tds RO Membrane Large Flow 1000 Gpd Water Purifier for Commercial 0

 

NSF Certified 1000 Tds RO Membrane Large Flow 1000 Gpd Water Purifier for Commercial 1NSF Certified 1000 Tds RO Membrane Large Flow 1000 Gpd Water Purifier for Commercial 2

FAQ:

1.Q: Can you put our Logo on the product?
A: Sure,we can offer logo customized survice. More than 200pcs, logo printing is for free.

2. Q: What about the lead time for mass production?
A: Honestly, it depends on the order quantity and the season you place the order. But as a professional manufacturer, we can always achieve your deadline.

3. Q: Can you offer sample before mass order?is it free or extra?
A:Yes samples will be kindly arranged for quality check, we could offer the sample for free charge but do not pay the cost of freight.please contact us for more details.

4. Q: Can I visit your factory?
A: Sure,welcome to contact us if you would like to visit.

5.Q: Are you manufacturer or trade company?
A: We are factory and OEM are available.

6. Q:What is your MOQ?
A:Our ready stock MOQ is 1pcs.For custom logo order MOQ is 500pcs,can mox different size.

7.Q: How about your product quality?
A:All of our product has been quality checked before shipping.Any quality problem when you receive the products, pls contact us.

8. Q:What is your products delivery time?
A:For ready stock, delivery day is within 7 days.

9: Q:What is your terms of payment?
A:30% T/T in advance ,balance before shippment or L/C.

 

Contact Details
Hangzhou Haina Environmental Protection Tech Co., Ltd.

Contact Person: Mr. Robert Wang

Tel: 0086 134 2961 7413

Send your inquiry directly to us (0 / 3000)