Send Message
Home ProductsNF RO Membrane

Reverse Osmosis Ro Membrane For 2000 Tds Water Filter Assembly Drinking Water Treatment

China Hangzhou Haina Environmental Protection Tech Co., Ltd. certification
China Hangzhou Haina Environmental Protection Tech Co., Ltd. certification
I'm Online Chat Now

Reverse Osmosis Ro Membrane For 2000 Tds Water Filter Assembly Drinking Water Treatment

Reverse Osmosis Ro Membrane For 2000 Tds Water Filter Assembly Drinking Water Treatment
Reverse Osmosis Ro Membrane For 2000 Tds Water Filter Assembly Drinking Water Treatment Reverse Osmosis Ro Membrane For 2000 Tds Water Filter Assembly Drinking Water Treatment

Large Image :  Reverse Osmosis Ro Membrane For 2000 Tds Water Filter Assembly Drinking Water Treatment

Product Details:
Place of Origin: Hangzhou,China
Brand Name: Hynamo/OEM/ODM
Certification: CE, RoHS, ISO9001, NSF
Model Number: 8040 NF
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: Negotiable
Packaging Details: 106.00cm * 23.00cm * 23.00cm
Delivery Time: depend on quantity
Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability: 30000 PCS /Month
Detailed Product Description
Type: RO Membrane Element Model NO.: 8040 NF
Desalination: 98% Gallons Per Day: 38m³/d
Test Solution: 2000 TDS Certification: CE, RoHS, CE, RoHS, NSF
Testing Pressure: 100psi Warranty: 3 Years
Highlight:

2000 tds membrane

,

ro membrane for 2000 tds

,

membrane for 2000 tds water

Industrial Nano Membrane Filter assembly for Drinking Water Treatment Methods

 

RO and NF membrane have the following differences:

1. Different filtering precision Reverse osmosis can remove the smallest solute with a molecular weight of less than 0.0001 microns. Due to its high filtration accuracy, it can filter out bacteria and various impurities in water. It is generally used in the manufacture of household purified water, industrial ultrapure water and medical ultrapure water. Nanofiltration can remove solutes with a molecular weight of about 0.001 microns, and is used in environments with slightly lower filtration accuracy requirements. It is generally used for water softening, micro-pollution desalination and the manufacture of industrial pure water.

2. Different desalination rates The desalination rate of reverse osmosis technology is 99.5%, which can effectively intercept all dissolved salts and various organic substances with a molecular weight greater than 100, while allowing small molecular groups to pass through. The nanofiltration system adopts the method of cross-flow filtration, and the desalination rate is between 80 and 90%. It is mainly used for the concentration and purification of macromolecular substances.

3. The proportion of "wastewater" produced is different Both reverse osmosis and nanofiltration purify water by pressurizing and electrifying, but the reverse osmosis technology due to the different composition of the membrane, the wastewater produced by reverse osmosis is 1:2-1:3, and the wastewater ratio of nanofiltration is 1:1: 1. In terms of water saving and environmental protection, reverse osmosis technology is more resource-intensive. Compared with nanofiltration technology, it has the advantages of partial removal of monovalent ions, low process osmotic pressure, low operating pressure, and energy saving.

 

Nanofiltration membranes can retain nanoscale (0.001 micron) substances. The operating range of the nanofiltration membrane is between ultrafiltration and reverse osmosis, the ability to intercept dissolved salts is between 20% and 98%, and the removal rate of soluble monovalent ions is lower than that of high-valent ions. Nanofiltration is generally used to remove surface Organic matter and pigments in water, hardness and radium in groundwater, and partial removal of dissolved salts, extraction and concentration of useful substances in food and pharmaceutical production. The operating pressure of the nanofiltration membrane is generally 3.5-30 bar.

 

Model Number Description 8040-NF
Performance &
Test Condition
The Desalination Rate % 98%
Water Rate GDP 10200
The Test pressure 100psi
Test solution Temperature 25± 1ºC
Test Solution Concentration NaCl 2.0-11.0
Recovery Of Single-Branch Membrane Element 15%
Feed water SDI 5

 

  1. When PH is above 10, the Maximum Temperature of Continuous Operation is 35ºC.
  2. Under certain conditions, the presence of free chlorine and other oxidants in the water may cause serious membrane damage, which doesn't belong to product warranty range.

 

Reverse Osmosis Ro Membrane For 2000 Tds Water Filter Assembly Drinking Water Treatment 0

Reverse Osmosis Ro Membrane For 2000 Tds Water Filter Assembly Drinking Water Treatment 1

Reverse Osmosis Ro Membrane For 2000 Tds Water Filter Assembly Drinking Water Treatment 2

 

FAQ:


Q: How to buy your products?

A: we need some essential information include sewage sources, sewage quality ( COD, BOD,SS),Required Filtered water quality, designed technological process, site engineering conditions (contact us for details),then we will design the uitable solutions for you and prepare to give you best price.

Q: How to pay?
A: TT and L/C are acceptable and TT will be more appreciated. 30% deposit before producing, 70% balanced against the copy of B/L.

Q: What is the delivery time?
A: Usually within 15days. Also depends on order quantities.

Q: Can the package be customized by our own logo ?
A: Yes, the package can be customized your logo, but the MOQ will be higher for which we can discuss as per the specific orders.

Q: How to install after the products arriving destination?
A: We will provide detailed illustrations to you. And we can also provide guide to your workers how to use it and how to maintain
it.

Contact Details
Hangzhou Haina Environmental Protection Tech Co., Ltd.

Contact Person: Mr. Robert Wang

Tel: 0086 134 2961 7413

Send your inquiry directly to us (0 / 3000)